If a proposed development, except developments limited to one- and two-family dwellings, involves the installation or alteration of outdoor lighting fixtures, an outdoor lighting plan shall be submitted and shall include the following information:

(1) A site plan, drawn to a scale of one (1) inch equaling no more than twenty (20) feet, showing the location, height, manufacturer, model, lamp type, lumen output and wattage of each outdoor lighting fixture in relationship to buildings, streets and parking areas.

(2) An iso-lux plan showing the levels of illumination, in foot-candles, that would result at ground level from the lighting installation.

(3) A certification that the lighting fixtures to be installed are fully shielded, cut off type fixtures that will not allow light dispersion or direct glare to shine above a ninety (90) degree horizontal plane from the base of the fixture.

(4) A certification that the exterior lighting will comply with the maintained horizontal illuminance recommendations of the Illuminating Engineering Society of North America.

(Rep&ReEn 1999-34)